Latest Version
|
Highlights
|
ORION Firmware
6.05.0924
Release Date
December 2024
|
▪RDM: Added functionality to send status and sensor data via ArtRdm to act as RDM Responder (#4640).
▪Now provides the version of the bootloader over RDM (#10871).
▪Now provides the used network Gateway in a specific Art-Net reply (#11038). |
ORION Firmware
6.04.0889
Release Date
May 2024
|
▪Art-Net 4: Added Squawking to the PollReply for better device identification in [software or hardware] controllers who support this feature (#10691). |
ORION Firmware
6.03.0862
Release Date
December 2023
|
▪Web Configuration: Improved the NetBIOS functionality by writing out the full address for web browsers (#10355).
▪Fixed an issue with the 'Node Report' field of the Art-Net implementation (#10370). |
ORION Firmware
6.02.7429
|
▪Web Configuration: Added NetBIOS functionality and information in the Device Information section to find and connect to devices using the NetBIOS name instead of the IP address (#10246). |
ORION Firmware
6.01.7426
Release Date
September 2023
|
▪Web Configuration: Checkmarks for checkboxes are now shown in the correct green accent color (#9963).
▪Fixed an issue that did ignore the BindIndex via ArtAdress; resulting in users only being able to set the first universe via ArtAddress (#10134). |
ORION Firmware
5.00.7417
Release Date
April 2023
|
▪Streamlined and freed up system resources (#7922, #8553). |
Bootloader
5.00.7418
Release Date
April 2023
|
▪Bootloader 5.0: Is able to provide the MAC address of the device over USB (#9389). |
ORION Firmware
4.07.7413
Release Date
April 2023
|
-
|
ORION Firmware
4.06.7408
Release Date
April 2023
|
▪Fixed an issue that uncontrolledly added zeros or possibly data to the HTML source code of the web configuration via a Firmware's hash value (#9569). |
ORION Firmware
4.05.7407
Release Date
January 2023
|
▪Improved reliability by ensuring that network settings are always properly saved (#9213).
▪Added automation options to set the value of the first pin for all other pins as well as automatic numbering of the DMX channels (#9291).
▪Added the development hash to the firmware version to the Device Information section (#9361). |
ORION Firmware
4.04.7403
|
-
|
ORION Firmware
4.03.7401
MADRIX Version
MADRIX 5.5c
Release Date
October 2022
|
-
|
ORION Firmware
4.02.7398
MADRIX Version
MADRIX 5.5b
Release Date
August 2022
|
▪The bootloader version can now be provided by the firmware over USB (#8874). |
ORION Firmware
4.01.7397
Bootloader
4.01.9396
MADRIX Version
MADRIX 5.5a
Release Date
July 2022
|
▪Added support for new hardware components (#8029, #8649).
▪Bootloader 4.0: Fixed an issue that did not always respond to firmware packets being sent over Art-Net (#8027).
▪Bootloader 4.0: Added support for new hardware components (#8028).
▪Bootloader 4.0: A single Art-Net PollReply is being sent after starting and remaining in the bootloader (#8032).
▪Fixed an issue that did not recognize hardware revision 1.3 (#8643). |
ORION Firmware
3.03.7390
MADRIX Version
MADRIX 5.4h
Release Date
April 2022
|
▪Web Configuration: Added the possibility to edit the ShortName identifier for Art-Net (#8159).
▪Web Configuration: Now shows the uptime of the device (#8183).
▪Optimized how value ranges are checked and processed (#8210). |
ORION Firmware
3.02.7387
MADRIX Version
MADRIX 5.4g
Release Date
March 2022
|
-
|
ORION Firmware
3.01.7385
MADRIX Version
MADRIX 5.4f
Release Date
January 2022
|
▪The bootloader can now read the hardware revision/model over USB (#7802).
▪Unified the way external voltages are calculated across the system (#7892).
▪Fixed a critical issue that could cause the bootloader on hardware revision 1.2 to freeze at startup with the status-LED Power being permanently on (#7808).
▪Fixed an issue that showed the external voltage for Power incorrectly on the web configuration (#7892).
▪Fixed a rounding error for external voltages shown on the web configuration (#7892).
▪Fixed a critical issue that did not apply new values when changing a large number of settings on the web configuration at once (#7895). |
ORION Firmware
3.00.7380
MADRIX Version
MADRIX 5.4e
Release Date
October 2021
|
▪Updated the system of the device (#6971, #7116, #7118, #7504, #7544).
▪Updated the bootloader of the device (#7652).
▪A single bootloader now supports both Ethernet ports (#7695).
▪Fixed an issue that still caused the status LED for USB to fade between red and green even if USB had been disconnected (#7543).
▪Fixed an issue with an incorrectly initialized register that could prevent the firmware update over Art-Net (#7615).
▪Fixed an issue that produced issues with the USB connection for the bootloader (#7653).
▪Fixed an issue that did not consistently initiate a PollReply when changing settings using the web configuration page (#7689). |
ORION Firmware
2.06.7355
MADRIX Version
MADRIX 5.4c
Release Date
July 2021
|
▪Note: Please reset the device to factory default settings –after– updating to this firmware version!
[Make sure to write down your current settings beforehand. All custom settings will be reset to their default values.]
▪Added two new measure functions: Time Interval (Short), Time Interval (Long) (#6906).
▪Web configuration page: Added the option to reboot the device (#7403).
▪Web configuration page: Added the option to reset the device to factory default settings (#7403).
▪Fixed an issue that could prevent changed settings from being saved in rare cases after a power cycle (#5382).
▪Fixed an issue that did not show the favicon in web browsers (#6460).
▪Fixed a critical issue that did not store values > 0 for minimum limits and set them to 0 again after a power cycle (#7400). |
ORION Firmware
2.05.7308
MADRIX Version
MADRIX 5.4b
Release Date
May 2021
|
-
|
ORION Firmware
2.04.7304
MADRIX Version
MADRIX 5.4a
Release Date
February 2021
|
▪Added support for hardware version/model 1.3 (#3581, #6459, #6830).
▪Web configuration page: Fixed an incorrect IP address shown for sACN Multicast Mode (#6562).
▪Web configuration page: Fixed that the Defaults buttons did not work correctly (#6907).
▪Fixed a critical issue that could halt the device when receiving an Art-Net OpIpProg request (#6852).
▪Fixed an issue that displayed voltage at pins other than the connected pin when using Counter (Hysteresis Threshold) as Pin Input Configuration (#6902). |
ORION Firmware
2.03.7291
MADRIX Version
MADRIX 5.4
Release Date
December 2020
|
▪Fixed minor issues. |
ORION Firmware
2.03.7261
MADRIX Version
MADRIX 5.3
Release Date
May 2020
|
▪Fixed an issue that could freeze the device if RDM packages were still sent to the device, although it communicated that it does not support RDM. |
ORION Firmware
2.03.7259
MADRIX Version
MADRIX 5.2
Release Date
November 2019
|
-
|
ORION Firmware
2.03.7252
MADRIX Version
MADRIX 5.1a
Release Date
August 2019
|
-
|
ORION Firmware
2.03.7236
MADRIX Version
MADRIX 5.1
Release Date
June 2019
|
▪Fixed an issue that only applied a new IP address that was set over USB after a power cycle.
▪Fixed an issue that did not allow the DMX Channel to be set with help of the MADRIX Device Configuration window over Ethernet.
▪Fixed an issue that allowed special characters and control characters [ASCII] in names and descriptions, which are not filtered out.
▪Fixed an issue that did not allow to retrieve the currently set Start Channel over USB when using the MADRIX Device Configuration window. |
ORION Firmware
2.02.7206
MADRIX Version
MADRIX 5.0e
Release Date
February 2019
|
▪During normal operation, pressing the Reset button now sends an Art-Net PollReply [e.g., Device Manager] and a MADRIX PollReply [MADRIX Device Configuration].
▪Fixed an issue that did only apply a new IP address after changing it over USB after disconnecting it from power first. |
ORION Firmware
2.01.7147
MADRIX Version
MADRIX 5.0d
Release Date
August 2018
|
▪Fixed a critical issue that could halt the device in rare cases. |
ORION Firmware
2.00.7140
MADRIX Version
MADRIX 5.0b
Release Date
July 2018
|
▪Initial firmware release. |